NovaSensor SDS069 atmospheric high-precision multi-channel particulate matter sensor is an environmental particulate matter detection device based on the principle of single particle laser scattering, also known as a laser particulate matter detection sensor. It is suitable for online monitoring occasions with accuracy requirements such as atmospheric environment, construction site dust, road dust, clean rooms, and environmental protection detection.
This infrared laser particle detection sensor adopts a professional optical path design and integrates multiple sets of optical lenses internally, with extremely high particle size recognition ability, which can accurately measure PM₁ and PM₂.₅, PM₁₀, TSP mass concentration.
The SDS069 particle sensor can choose different sampling methods for fans or air pumps according to the scene, which is convenient for integrated development and use.

● Professional optical design, multiple groups of optical lenses
● Multistage signal processing, high speed AD acquisition chip
● Long running time without fault, stable performance
● Improved performance, all industrial devices, optional heating dehumidification
● 4 channel output, can monitor PM1.0, PM2.5, PM10, TSP
Nova SDS069 laser particle sensor is widely used in scenarios that require online monitoring of particulate matter, such as atmospheric environment monitoring, construction site dust, clean workshops, and air quality monitoring.
| NO. | Project | Parameter | Notes | |||
| SDS069-N | SDS069-F | SDS069-P | SDS069s | |||
| 1 | Range | 0.0~10.0mg/m³(Can detect 100mg/m³) | TSP | |||
| 2 | Sleeping power | 0.24W | ||||
| 3 | Temp.Range | -20℃~60℃ | ||||
| 4 | Humidity range | 0~99%RH | ||||
| 5 | Response time | 1S | ||||
| 6 | Interface | Uart TTL(customizable) | ||||
| 7 | Protocol | Modbus-RTU | ||||
| 8 | Relative errorr | PM₁ :±10%&±8μg/m³MAX;PM₂ 5:±10%&±8μg/m³MAX; PM₁ :±10%&±10μg/m³MAX;TSP:±18%&±30μg/m³MAX; | @25℃ 50%RH | |||
| 9 | Size | 88*39.5*27mm | 88.5*85.5*30mm | 88.5*151*37mm | Kernel(No filter element):88*52*27mm; Fan:88.5*98*30mm; Pump:85.5*163.5*37mm | |
| 10 | Sampling mode | / | Fan | Pump | / | |
| 11 | Power supply | 5V 1A, Ripple<50mV | 5V 1A, Ripple<50mV | 12V 2A, Ripple<200mV | Fan:5V 1A,Ripple<50mV; Pump:12V 2A,Ripple<200mV | |
| 12 | Working current | <200mA | <300mA | <400mA | Fan:<300mA;Pump:<400mA | |